Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros

Tipo del documento
Intervalo de año
1.
Int J Environ Res Public Health ; 20(5)2023 03 05.
Artículo en Inglés | MEDLINE | ID: covidwho-2256114

RESUMEN

Since the beginning of March 2022, a new round of COVID-19 outbreaks in Shanghai has led to a sharp increase in the number of infected people. It is important to identify possible pollutant transmission routes and predict potential infection risks for infectious diseases. Therefore, this study investigated the cross-diffusion of pollutants caused by natural ventilation, including external windows and indoor ventilation windows, under three wind directions in a densely populated building environment with the CFD method. In this study, CFD building models were developed based on an actual dormitory complex and surrounding buildings under realistic wind conditions to reproduce the airflow fields and transmission paths of pollutants. This paper adopted the Wells-Riley model to assess the risk of cross-infection. The biggest risk of infection was when a source room was located on the windward side, and the risk of infection in other rooms on the same side as the source room was large in the windward direction. When pollutants were released from room 8, north wind resulted in the highest concentration of pollutants in room 28, reaching 37.8%. This paper summarizes the transmission risks related to the indoor and outdoor environments of compact buildings.


Asunto(s)
COVID-19 , Contaminantes Ambientales , Humanos , Modelos Teóricos , China , Brotes de Enfermedades , Ventilación
2.
Journal of Building Engineering ; : 106049, 2023.
Artículo en Inglés | ScienceDirect | ID: covidwho-2221042

RESUMEN

A sudden outbreak of COVID-19 occurred in December 2019 and its rapid spread over the last two years caused a global pandemic. A special airborne transmission via aerosols called interunit dispersion is risky in a high-density urban environment, which needs more attention. In order to identify the source location of pollutants or viruses under the interunit transmission condition with natural ventilation, this study adopted the inverse Computational Fluid Dynamics (CFD) simulation with the adjoint probability method. The detailed process of the inverse modeling was presented. Also, the possible interunit transmission routes of the pollutants or viruses were analyzed. A three-story building model with single-sided openings was built. Six different combinations of fixed sensor locations were tested, and it was determined that setting sensors in the four corner regions of the building was the optimist strategy. A total of 25 cases with five different wind directions (0°, 45°, 90°, 135°, and 180°) were tested to verify the accuracy of the source location with inverse modeling. The results showed that 67%–78% of the rooms in the building can be identified with a limited number of pollutant sensors and all rooms can be identified with one additional sensor in the downstream room of the building under different wind direction. This research revealed that the inverse modeling method could be used to identify the pollutant source in the coupled indoor and outdoor environment. Further, this work can provide guidance for the pollutant monitor positions in the applications.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA